Removal

PERFORMANCE ORDER
1. Release a fixing clip and disconnect a rope from the lever of a butterfly valve.
2. Remove a rope braid from a fixing arm.
3. Release fixing clips and remove the finishing panel.
4. Get a fixing pin and remove an air branch pipe.
5. Disconnect a rope from an accelerator pedal (it is specified by an arrow) and remove it.

Installation

Installation is carried out to the sequences, the return to removal.

Adjustment

Adjust a tension of a rope and establish into place a fixing clip.