6.3. Accumulator
RemovalInstallation
Installation is carried out to the sequences, the return to removal. Grease with technical vaseline of the plug of the accumulator before connection of wires.
THE ORDINARY ACCUMULATOR AND THE ACCUMULATOR DEMANDING SMALL MAINTENANCE
Check
It is recommended to check the specific density of electrolyte each three months for accumulator charging definition.
Air temperature is above 25 °C
|
Air temperature is below 25 °C
| |
The accumulator is completely charged
|
1,210 – 1,230
|
1,270 – 1,290
|
The accumulator is charged for 70%
|
1,170 – 1,190
|
1,230 – 1,250
|
The accumulator is discharged
|
1,050 – 1,070
|
1,110 – 1,130
|
Check electrolyte density in each section of the accumulator. If the specific density of electrolyte between sections differs more, than on 0,040, the accumulator needs to be replaced.
THE ACCUMULATOR WHICH IS NOT DEMANDING MAINTENANCE
Check
PERFORMANCE ORDER | ||
|
THE ORDINARY ACCUMULATOR AND THE ACCUMULATOR DEMANDING SMALL MAINTENANCE
Charging
At accumulator charging temperature of electrolyte should not exceed 37,8 °C.
PERFORMANCE ORDER | ||
|
THE ACCUMULATOR WHICH IS NOT DEMANDING MAINTENANCE
Charging
Charging of this type of accumulators demands more time, than charging of ordinary accumulators. Exercises need to be done at a voltage of 13,9-14,9 Volts, current of charging should not exceed 25 Amperes.