5.1.17.5. Elements of system of recirculation of exhaust gases
RECIRCULATION VALVE
On DOHC engines of 2,0 l the valve is located behind a head of the block of cylinders. On engines of 2,5 and 3,0 l of klapn it is located on a head of the right number of cylinders.
PERFORMANCE ORDER |
SOHC engine of 2,0 l |
1. Remove a casing of wires from a cover of a head of the block of cylinders. |
2. Disconnect the socket of connection and a vacuum hose from the valve. |
3. Turn off fixing screws and remove the valve. |
4. Installation is carried out to the sequences, the return to removal. |
DOHC engine of 2,0 l |
5. See subitem 2-4. |
2,5 and 3,0 l engines |
|
6. Disconnect the socket of connection of the valve. |
|
7. Turn off fixing screws (are specified by shooters) and remove the valve. |
8. Installation is carried out to the sequences, the return to removal. |
|
RECIRCULATION VALVE TUBE
PERFORMANCE ORDER |
2,5 and 3,0 l engines |
|
1. Turn off nuts of connections. |
|
2. Pick up the phone. |
3. Installation is carried out to the sequences, the return to removal. |
|
RECIRCULATION VALVE ADAPTER
PERFORMANCE ORDER |
2,5 and 3,0 l engines |
1. Remove the valve of recirculation and a tube. |
2. Remove a fixing arm of a rope of an accelerator. |
3. Turn off fixing bolts and remove an adapter. |
4. Installation is carried out to the sequences, the return to removal. |
|